RDC5 series AC contactors are mainly used in circuits with AC 50HZ rated operating voltage to 690V rated working current up to 95A It is used for long-distance connection and disconnection of circuits, and can be directly plugged into the thermal relay to form an electromagnetic starter to protect against possible occurrences Operate overloaded circuits. The contactor can also be assembled with building block-type auxiliary contact groups, air delay heads, mechanical interlocking mechanisms and other accessories. It is composed of a delay contactor, a reversible contactor, and a star triangle starter. The products comply with: GB/T14048.4, IEC 60947-4-1 and other national standards.
Feature
Parameters
Contactor Model |
RDC5 - 06 |
RDC5 - 09 |
RDC5 - 12 |
RDC5 - 18 |
RDC5 - 25 |
RDC5 - 32 |
RDC5 - 38 |
RDC5 - 40 |
RDC5 - 50 |
RDC5 - 65 |
RDC5 - 80 |
RDC5 - 95 |
|
Poles |
3 poles |
||||||||||||
Rated Insulation Voltage (Ui) V |
690 |
||||||||||||
Rated Operating Voltage (Ue) V |
380/400, 660/690 |
||||||||||||
Conventional Heating Current (Ith) A |
16 |
25 |
25 |
32 |
40 |
50 |
50 |
50 |
60 |
80 |
110 |
110 |
|
Rated Operating Current (Ie) |
AC - 3 380/400V A |
6 |
9 |
12 |
18 |
25 |
32 |
38 |
40 |
50 |
65 |
80 |
95 |
AC - 3 660/690V A |
3.8 |
6.6 |
8.9 |
12 |
18 |
22 |
22 |
34 |
39 |
42 |
49 |
49 |
|
AC - 4 380/400V A |
2.6 |
3.5 |
5 |
7.7 |
8.5 |
12 |
14 |
18.5 |
24 |
28 |
37 |
44 |
|
AC - 4 380/400V A |
1 |
1.5 |
2 |
3.8 |
4.4 |
7.5 |
8.9 |
9 |
12 |
14 |
17.3 |
21.3 |
|
Rated Operating Power (Pe) |
AC - 3 380/400V kw |
2.2 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
22 |
30 |
37 |
45 |
AC - 3 660/690V kw |
3 |
5.5 |
7.5 |
10 |
15 |
18.5 |
18.5 |
30 |
33 |
37 |
45 |
45 |
|
AC - 4 380/400V kw |
1.1 |
1.5 |
2.2 |
3.3 |
4 |
5.4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
|
AC - 4 660/690V kw |
0.75 |
1.1 |
1.5 |
3 |
3.7 |
5.5 |
6 |
7.5 |
10 |
11 |
15 |
18.5 |
|
Mechanical Life (10,000 times) |
1200 |
1200 |
1200 |
1200 |
1200 |
1000 |
1000 |
1000 |
900 |
900 |
650 |
650 |
|
Electrical Life |
AC - 3 (10,000 times) |
110 |
110 |
110 |
110 |
110 |
90 |
90 |
90 |
90 |
90 |
65 |
65 |
AC - 4 (10,000 times) |
22 |
22 |
22 |
22 |
22 |
22 |
22 |
17 |
17 |
17 |
11 |
11 |
|
Operating Frequency |
AC - 3 (times/hour) |
1200 |
1200 |
1200 |
1200 |
1200 |
600 |
600 |
600 |
600 |
600 |
- |
- |
AC - 4 (times/hour) |
- |
- |
- |
- |
- |
300 |
300 |
300 |
300 |
300 |
- |
- |